技术文章/ARTICLE
新消息:ted pella三角抛光器涉及哪些领域的行业应用?
点击次数:1098 发布时间:2024/4/29 11:09:38
新消息:ted pella三角抛光器涉及哪些领域的行业应用?
http://www.app17.com/c153392/products/d13365304.html
The PELCO® Tripod Polisher™ 590 was designed by researchers at the IBM East Fishkill Laboratory* to accurately prepare TEM and SEM samples of pre-specified, micron-sized regions. For TEM samples, this technique has been used successfully to limit ion milling times to less than 15 minutes and, in some cases, has eliminated the need for ion milling. Although this technique was designed for preparing semiconductor cross-sections, it has been used to prepare both plan-view and cross-section samples from such diverse materials as ceramics, composites, metals, and geological samples.
Features & Benefits
Operation - Standard Technique The PELCO® Tripod Polisher™ 590 can be used to prepare a sample for both SEM and TEM cross-sectional analysis. To accomplish this, the sample is mounted on the face of a special SEM stub which is clamped into the slotted L-bracket of the PELCO® Tripod Polisher™ 590. Initial grinding is done on a 15μm metal bonded diamond disc. Further lapping and polishing continues with a succession of diamond films ranging in size from 30μm to 0.5μm. The final polish is done with a colloidal silica suspension. As lapping progresses, the two rear micrometers are used to adjust the plane of polish. With periodic examinations in an inverted microscope, the plane of polish is adjusted until it is parallel to the plane of interest. At this point the SEM stub may be moved to an ion mill for a quick milling to remove fine scratches, polishing debris and to give the surface ography prior to SEM analysis. The SEM stub can be mounted directly in the SEM for analysis. When analysis is complete, a TEM sample of the same area is made. The sample is removed from the SEM stub and attached to a single aperture TEM grid. The slotted L-bracket is removed and the TEM grid is attached to the round sample mount which is affixed to the center of the polisher. The sample is now mechanically thinned using Diamond Lapping Film. During this process the sample is periodically examined in an inverted microscope and the micrometers are adjusted to maintain the correct plane of polish. The sample is FINAL polished to 1μm or less and then ion milled for up to 15 minutes. Operation - Wedge Technique Wedge polishing technique can be used either in conjunction with ion milling (common for cross-sections) or electropolishing, or in some cases where preferential thinning, amorphization, and ography that can occur in ion-milled samples is unacceptable, mechanically polish the sample to electron transparency. With this technique the SEM stub is replaced, in the slotted L-bracket, with a Pyrex® insert. The sample is mounted on the bottom of the insert and the two rear micrometers are adjusted and the micrometer nearest the sample is retracted to produce a wedge shape as material is removed from the sample. The typical wedge angle is 1.5-2 degrees. The sample, with the features of interest at the apex of the wedge, is thinned until the area of interest is 3-5um thick if final polishing by other methods or ~1μm thick if mechanically finishing, on a succession of diamond lapping films. The sample is then final polished, either mechanically on a final polishing cloth such as our MultiTex Cloth (#816-12) with a colloidal silica suspension, or glued to a single aperture TEM grid and removed from the Pyrex® insert for final polishing by other methods. |
Ordering Information |
Prod #DescriptionUnit 59100PELCO® Tripod Polisher™ 590TEM precision sample thinning for TEMeach Includes: Base with 3 Micrometer Assemblies, Hex Driver Set, Sample Mounting Wax, Case, 590TEM accessories listed in table below59200PELCO® Tripod Polisher™ 590SEM precision sample preparation for SEMeach Includes: Base with 2 Micrometer Assemblies, Hex Driver Set, Sample Mounting Wax, Case, 590SEM accessories listed in table below59300PELCO® Tripod Polisher™ 590TS configured for SEM and TEM sample preparationeach Includes: Base with 3 Micrometer Assemblies, Hex Driver Set, Sample Mounting Wax, Case, 590TS accessories listed in table below |